WELCOME TO OUR BLOG

We're sharing knowledge in the areas which fascinate us the most
click

Solid Insulated Ring Main Unit (RMU): Specifications & Application Cases | Xinhong Electrical

By Xinhomg electrical October 10th, 2026 24 views

Introduction

A solid insulated ring main unit (solid insulated RMU) is a fully sealed, metal-clad medium voltage switchgear built for ring network power distribution. Unlike conventional SF6 gas-insulated RMU, all live conductive parts are encapsulated in high-performance epoxy resin solid insulation, paired with vacuum interrupters for arc extinction. It eliminates SF6 greenhouse gas, delivers stable insulation performance, and reduces maintenance workload, making it a preferred eco-friendly MV switchgear for modern power grids worldwide.

As a professional solid insulated RMU manufacturer from China, Xinhong Electrical designs and produces solid insulated ring main units complying with IEC standards. Our solid insulated RMU features modular construction, compact footprint, strong environmental adaptability and optional smart grid integration. This article covers core specifications, key benefits and typical use cases to help engineers, EPC contractors and utility buyers select suitable solid insulated RMU for distribution projects.

What is Solid Insulated RMU?

Solid insulated RMU is a compact modular switchgear for 12kV medium voltage three-phase AC distribution systems. The high-voltage live circuit, vacuum interrupter and busbar are fully cast inside epoxy resin. Functional units connect via shielded solid insulated busbars. The whole primary circuit is isolated from humidity, dust, pollution and condensation, achieving fully insulated and fully sealed operation.

The equipment integrates load break switch, circuit breaker, fuse combination unit, PT unit and metering unit. It supports ring network power supply and terminal power supply, and can be equipped with protection relays and communication modules to realize distribution automation for smart grid projects.

Core Technical Specifications of Xinhong Electrical Solid Insulated Ring Main Unit

Item Parameter
Rated Voltage 12kV
Rated Frequency 50Hz / 60Hz
Rated Current 630A, 1250A
Rated Short-time Withstand Current 20kA, 25kA, 31.5kA (4s)
Power Frequency Withstand Voltage 42kV phase to earth / phase to phase
Lightning Impulse Withstand Voltage 75kV
Partial Discharge ≤20pC
Enclosure Protection Class IP4X
Insulation Medium Epoxy resin solid insulation, SF6-free
Arc Extinguishing Vacuum interrupter
Compliance Standard IEC 62271-200, ISO, CE, CB

Note: Xinhong Electrical supports customized solid insulated RMU configuration according to project requirements, including feeder quantity, protection scheme and smart monitoring functions.

Key Advantages of Xinhong Electrical Solid Insulated RMU

  1. SF6-free & Eco-friendly No SF6 greenhouse gas, meets global low-carbon grid requirements, no gas leakage risk, simplifies transportation, installation and waste disposal.
  2. Fully Sealed & Environment Resistant Primary live parts encapsulated by epoxy resin. Stable operation in high humidity, heavy dust, coastal salt fog and high altitude environments. Less affected by outdoor and underground installation conditions.
  3. Compact Modular Design Small installation footprint. Modular units can be freely combined and expanded, easy for pre-installation inside box-type substations and compact kiosk substations.
  4. Low Maintenance & High Safety Fully shielded live components, low partial discharge, arc-resistant cabinet structure. Long service cycle with minimal routine maintenance, reduces on-site operation risk for field crews.
  5. Smart Grid Ready Reserved interface for sensors, RTU and protection relays. Supports remote monitoring, fault location and automatic sectionalizing for smart urban distribution networks.

Typical Use Cases for Solid Insulated Ring Main Unit

Solid insulated RMU is widely adopted for indoor and outdoor medium voltage distribution projects, especially where space is limited or SF6 restriction applies.

1. Urban & Municipal Power Grid Upgrade

City cable ring networks, small secondary substations, underground power rooms, tunnel power distribution and urban grid renovation projects. Its compact size fits narrow underground spaces and dense urban areas.

2. Renewable Energy Projects

Distributed solar PV stations, wind farms and battery energy storage systems (BESS). Solid insulated RMU provides reliable grid connection, fault isolation and power switching for new energy plants.

3. Commercial & Civil Construction

High-rise buildings, residential communities, shopping malls, hospitals, airports, rail transit and metro power supply systems. Continuous power supply capability ensures critical loads stay online during grid faults.

4. Industrial & Mining Projects

Industrial parks, manufacturing plants, chemical and mining facilities. The robust anti-pollution and anti-corrosion performance adapts to harsh industrial environments.

5. Box-type / Packaged Substations

Perfect matching equipment for prefabricated box substations. Solid insulated RMU works together with distribution transformers and low-voltage panels as a complete power distribution package.

Solid Insulated RMU vs SF6 Gas Insulated RMU

  • Solid Insulated RMU: SF6-free, epoxy encapsulation, less maintenance, higher initial cost, ideal for environmentally restricted & confined sites
  • SF6 Gas Insulated RMU: Small cabinet size, mature technology, requires gas leakage inspection, greenhouse gas concerns, strict gas handling rules

For projects with carbon reduction requirements or sites with poor ventilation, Xinhong Electrical solid insulated RMU becomes a more sustainable long-term option.

Why Choose Xinhong Electrical Solid Insulated RMU

Xinhong Electrical is a China-based manufacturer of medium voltage power equipment with rich experience in MV switchgear production. Our solid insulated ring main units are factory tested and certified by ISO, CE and CB.

We provide:

  • Customized solid insulated RMU configurations for global projects
  • Complete technical documentation, type test reports and drawing support
  • One-stop solution including design, manufacturing, factory testing and after-sales technical guidance
  • Export packaging and shipment for overseas EPC, utility and contractor clients

If you need solid insulated RMU quotation or technical proposal for your power distribution project, contact our engineering team for detailed support.

Conclusion

Solid insulated ring main unit is a sustainable, safe and reliable medium voltage switchgear solution for modern ring distribution networks. With SF6-free solid insulation, vacuum interruption, compact structure and wide environmental tolerance, solid insulated RMU has become a mainstream choice for urban grid renovation, new energy, rail transit and industrial power projects.

Xinhong Electrical from China supplies high-quality solid insulated RMU with full certifications and custom service. Talk to our team to find the optimal solid insulated ring main unit solution for your next power project.

Jiangsu Xinhong Electrical: Reliable ≤35kV Transformer Solution Provider
Previous
Jiangsu Xinhong Electrical: Reliable ≤35kV Transformer Solution Provider
Read More
Fully sealed oil immersed distribution transformer for Kazakhstan rural electrification, Xinhong Electrical China factory
Next
Fully Sealed Oil Immersed Distribution Transformer for Kazakhstan Rural Electrification
Read More