Our 3000kVA oil‑immersed distribution transformer is a robust outdoor‑type power solution for 11kV,15kV and 33kV medium‑voltage systems. As a professional China transformer manufacturer Xinhong Electrical, we provide standardized and customizable oil‑immersed transformers for global power transmission‑distribution projects.
This three‑phase oil immersed transformer uses mineral insulating oil for cooling and insulation. The corrugated tank structure adapts to outdoor harsh working conditions, resisting humidity, dust and temperature variation. Optimized core and winding design effectively reduces no‑load loss and load loss, cutting long‑term operation cost for end‑users.
All units strictly follow IEC60076 international standard, and pass ISO, CE, CB certification. We support custom‑made on voltage ratio, vector group, impedance voltage and cooling mode ONAN/ONAF. Suitable for power utility, factory, mining site, solar‑wind power station and rural grid upgrade projects across Africa, Southeast Asia, Middle East and Latin America.
We offer complete technical datasheets, factory test reports and after‑sales technical support. Contact us for quotation and project‑oriented technical proposal.
Our 3000kVA oil‑immersed distribution transformer is a robust outdoor‑type power solution for 11kV,15kV and 33kV medium‑voltage systems. As a professional China transformer manufacturer Xinhong Electrical, we provide standardized and customizable oil‑immersed transformers for global power transmission‑distribution projects.
This three‑phase oil immersed transformer uses mineral insulating oil for cooling and insulation. The corrugated tank structure adapts to outdoor harsh working conditions, resisting humidity, dust and temperature variation. Optimized core and winding design effectively reduces no‑load loss and load loss, cutting long‑term operation cost for end‑users.
All units strictly follow IEC60076 international standard, and pass ISO, CE, CB certification. We support custom‑made on voltage ratio, vector group, impedance voltage and cooling mode ONAN/ONAF. Suitable for power utility, factory, mining site, solar‑wind power station and rural grid upgrade projects across Africa, Southeast Asia, Middle East and Latin America.
We offer complete technical datasheets, factory test reports and after‑sales technical support. Contact us for quotation and project‑oriented technical proposal.
A: The 3000kVA oil‑immersed transformer is a 3MVA three‑phase medium‑voltage distribution transformer, using mineral insulating oil as cooling and insulation medium. It is outdoor‑type equipment widely used for power grid, industrial plants, mining and renewable‑energy projects.
Xinhong Electrical 3000kVA oil immersed transformer follows IEC60076 standard with ISO, CE, CB certifications. It adopts copper winding and grain‑oriented silicon‑steel core, features low power loss and stable performance. This unit is designed to step‑down medium‑voltage power to low‑voltage 400V for end‑user consumption. It supports ONAN / ONAF cooling modes and various custom options for global power distribution projects.
A: For our 3000kVA three‑phase outdoor distribution transformer, the available high‑voltage primary options are 11kV, 15kV, 33kV. The standard secondary low voltage is 0.4kV (400V).
Other voltage ratios can be customized according to project requirements. Default vector group is Dyn11, frequency supports 50Hz or 60Hz. It is suitable for most medium‑voltage power systems in Africa, Southeast Asia, Latin‑America and other overseas markets. Please send us your exact voltage class, impedance and site condition for a precise quotation.
A: Standard cooling modes are ONAN (Oil Natural Air Natural) and optional ONAF (Oil Natural Air Forced). ONAN works under normal load; ONAF can improve overload capacity when equipped with external cooling fans.
A: Yes. Our 3000kVA oil‑immersed distribution transformer is outdoor‑type with corrugated radiator tank. It can adapt to complex outdoor environment, wide ambient temperature range from ‑25℃ to +40℃. For sites over 1000 m altitude, we can provide high‑altitude modified version.