Why Dry-Type Transformers Are Safer Than Oil-Immersed Transformers

Jan 5th,2026 306 Views
As an indispensable core equipment in power systems, transformer safety directly relates to the stable operation of the entire power grid and the safety of personnel and property. In the development of transformer technology, dry-type transformers and oil-immersed transformers are the two main types. With technological progress and increasing safety requirements, dry-type transformers have been widely used due to their outstanding safety performance. This article will elaborate on the safety advantages of dry-type transformers over oil-immersed transformers from multiple dimensions.

I. Fire Safety

The most prominent safety advantage of dry-type transformers lies in their excellent fire resistance. Oil-immersed transformers use mineral oil as the insulation and cooling medium, which is a flammable substance. When a short circuit or overload fault occurs inside the transformer, high-temperature electric arcs may be generated, igniting the transformer oil and causing severe fire accidents. Many major power accidents in history are related to oil-immersed transformer fires.
In contrast, dry-type transformers adopt solid insulation materials (such as epoxy resin, Nomex paper, etc.) and do not use any flammable liquids at all. These materials have a high flame-retardant rating and will not burn even under high-load operation or short-circuit conditions. The insulation system of modern dry-type transformers usually meets the UL94 V-0 flame-retardant standard, which can self-extinguish immediately after the open flame is removed, greatly reducing the fire risk.
In places with strict fire protection requirements, such as high-rise buildings, underground facilities, chemical plants, airports, and data centers, dry-type transformers have become the preferred choice. Once a fire breaks out in these places, the consequences will be unimaginable, and dry-type transformers fundamentally eliminate the fire hazard caused by the transformers themselves.

II. Environmental Safety

The insulating oil used in oil-immersed transformers may cause serious environmental pollution. Transformer oil is mainly composed of mineral oil and contains a variety of harmful chemical substances. When a transformer leaks or explodes, a large amount of insulating oil will leak out, polluting soil and water sources. In addition, the disposal of waste transformer oil is also an environmental problem; improper disposal will cause persistent environmental pollution.
Dry-type transformers do not use any oil-based substances, completely avoiding oil pollution problems. Even if a fault or equipment damage occurs, no harmful substances will be released into the environment. This feature makes dry-type transformers particularly suitable for installation in ecologically sensitive areas, near drinking water sources, or places with strict environmental requirements.
From the perspective of the whole life cycle, the environmental advantages of dry-type transformers are more obvious. It does not require regular replacement and disposal of insulating oil, reducing the generation of hazardous waste. When the equipment is scrapped, the recycling and disposal of dry-type transformers are simpler and more environmentally friendly, and most materials can be recycled.

III. Operational and Maintenance Safety

There are various potential safety hazards in the operation and maintenance of oil-immersed transformers. First, routine maintenance work such as checking oil levels and taking oil samples requires operators to come into contact with transformer oil, which may affect health after long-term exposure. Second, oil-immersed transformers need regular oil quality testing, filtration, and replacement, and these tasks all carry the risk of oil leakage and pollution.
Dry-type transformers require almost no special maintenance, and their "maintenance-free" feature greatly reduces the safety risks for operators. Since there is no oil system, there is no need for oil treatment, oil testing, and other work, reducing the chance of personnel contacting hazardous substances. At the same time, it also avoids oil leakage accidents caused by improper maintenance.
During operation, oil-immersed transformers may experience problems such as abnormal oil levels and excessive oil temperature, which need to be handled in a timely manner; otherwise, serious accidents may occur. In contrast, the operating parameters of dry-type transformers are relatively stable, and the fault early warning system is simpler and more reliable, reducing the possibility of sudden accidents.

IV. Installation Site Safety

Due to the risks of oil leakage and fire, oil-immersed transformers have strict requirements for installation sites. They usually require a dedicated transformer room equipped with safety facilities such as oil pits, firewalls, and fire-fighting systems. These requirements increase engineering costs and space occupation, making it difficult to apply in space-constrained places.
Dry-type transformers can be safely installed in various environments, including indoor, outdoor, basements, and even densely populated areas. They do not require auxiliary facilities such as oil pits and can be directly installed near the load center, saving space and cable costs. This installation flexibility is particularly suitable for urban power grid transformation, commercial buildings, rail transit, and other space-constrained occasions.
In special environments such as high altitude, humidity, and heavy dust, dry-type transformers also show better adaptability. Oil-immersed transformers may experience problems such as oil deterioration and reduced insulation performance in these environments, while dry-type transformers can maintain stable safety performance through special designs and material selection.

V. Electrical Safety

From the perspective of electrical safety, dry-type transformers also have obvious advantages. The insulating oil of oil-immersed transformers may age, absorb moisture, or become contaminated during long-term operation, leading to reduced insulation performance and increased risks of internal discharge and short circuits. In contrast, the solid insulation system of dry-type transformers has stable performance, is not easily affected by the environment, and maintains good insulation strength.
Dry-type transformers usually adopt Vacuum Pressure Impregnation (VPI) or casting processes to form a uniform and dense insulation structure with extremely low partial discharge. This structure can effectively prevent electrical treeing and insulation breakdown, greatly extending the safe service life of the equipment.
In terms of overload capacity, although dry-type transformers have relatively weak heat dissipation capacity, modern designs have significantly improved their short-term overload capacity by optimizing cooling air ducts and using high-temperature insulation materials. More importantly, unlike oil-immersed transformers, dry-type transformers do not generate flammable gases when overloaded, providing a higher safety margin.

VI. Safety of Fault Consequences

When a serious fault occurs, the consequences of the two types of transformers are significantly different. Internal faults of oil-immersed transformers may cause a sudden increase in pressure, leading to tank explosion. The sprayed high-temperature oil mist may form a large-area fire. Such faults often result in severe equipment damage and secondary disasters.
In the event of a fault, dry-type transformers will at most suffer local insulation burnout and will not cause explosive damage. Faults are usually confined to a small range and will not affect other equipment. This "fault tolerance" makes dry-type transformers irreplaceable in important power systems.
In addition, the inspection and handling of dry-type transformers after faults are safer and simpler. There is no need to handle a large amount of leaked oil, no risk of environmental pollution, and maintenance personnel can directly approach the equipment for inspection and repair.

VII. Health and Safety

The mineral oil used in oil-immersed transformers may contain harmful substances such as polycyclic aromatic hydrocarbons, which may affect the health of staff after long-term exposure. Transformer oil may also decompose to produce toxic gases at high temperatures. In contrast, dry-type transformers do not use these harmful substances at all, creating a healthier working environment.
In terms of electromagnetic safety, dry-type transformers usually adopt better shielding designs, with superior leakage magnetic field control, reducing the potential impact of electromagnetic fields on the surrounding environment and personnel. This is particularly important for places with strict requirements on the electromagnetic environment, such as hospitals and schools.

Conclusion

Based on the above analysis, dry-type transformers show significant advantages in fire safety, environmental protection, maintenance, installation, electrical performance, fault consequences, and health and safety. With the progress of insulation material technology and the improvement of manufacturing processes, the safety performance of dry-type transformers will be further improved. In today's context of increasing requirements for safety and environmental protection, dry-type transformers are becoming the mainstream choice in the medium and low-voltage fields. Of course, oil-immersed transformers still have certain advantages in large-capacity and ultra-high-voltage fields, but in most application scenarios, dry-type transformers are undoubtedly a safer and more reliable choice. In the future, with the application of new materials and the development of intelligent technology, the safety performance of dry-type transformers will be further enhanced, making greater contributions to the safe operation of power systems.