• Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV

Epoxy resin cast dry-type transformer 6KV-35KV

The 11KV 22KV 33KV 35KV class SC(B)10, SC(B)11, SC(B)12, SC(B)13, SC(B)14, and SC(B)18 epoxy resin cast dry-type transformers are professionally designed low-noise, low-loss power transformer solutions. As an upgraded replacement for traditional oil-immersed distribution transformers, this dry-type transformer utilizes advanced technology and is particularly suitable for applications with high safety and reliability requirements.

  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV
  • Epoxy resin cast dry-type transformer 6KV-35KV

Description

Core Application Scenarios

Urban power grid renovation and upgrading

Power supply systems for high-rise buildings and commercial centers 

Public facilities such as theaters, hospitals, and hotels 

Transportation hubs (tunnels, subways, stations, docks, airports)

Underground power stations and laboratory facilities 

Packaged substation systems

Locations with stringent fire safety requirements

 

Technical Features and Advantages

1. Advanced Structure and Materials 

High-Voltage Winding: Manufactured with high-quality copper wire 

Low-Voltage Winding: Utilizes copper wire or copper foil winding technology 

Insulation System: Filled and wrapped with glass fiber mat, vacuum-cast with epoxy resin 

Structural Strength: Cures to form a solid cylindrical monolithic unit with high mechanical strength 

2. Outstanding Safety Performance 

Flame Retardant & Explosion-Proof: Insulation materials possess self-extinguishing properties, complying with strict safety standards 

Environmentally Friendly: No arc generation during short circuits, and no release of toxic or harmful gases under high temperatures 

Anti-Corrosion Design: Core clamps feature special anti-corrosion protective coatings 

High Adaptability: Capable of stable operation in 100% humidity and harsh environments

3. Excellent Electrical Performance 

Low-Loss Design: Significant energy-saving effect, economical and efficient operation 

High Surge Withstand: Excellent resistance to short-circuit and lightning impulse 

Superior Heat Dissipation: Thin-layer resin design ensures high heat dissipation efficiency
 

4. Operation and Maintenance Advantages 

Maintenance-Free Design: Reduces operational costs and maintenance workload 

Flexible Installation: Compact size and light weight save installation space and cost

Ready for Use: Requires no oil containment pits, fire-fighting facilities, or other supporting equipment

 

Cooling System Configuration 

Standard Cooling: Air Natural cooling (AN)

Optional Configuration: Air Forced cooling system (AF) to enhance short-time overload capacity

Protection Compatibility: Suitable for transformers of any protection class

 

Enclosure Protection Rating 

IP20 Rating: Prevents ingress of solid objects larger than 12mm in diameter 

IP23 Rating: Additionally prevents water ingress from droplets within a 60° angle, suitable for outdoor installation

Material Options: Stainless steel or aluminum alloy enclosure for enhanced durability

 

Installation Economic Benefits 

Decentralized Installation: Can be installed at load centers, close to points of consumption 

Line Optimization: Reduces line costs and low-voltage facility expenses 

Space Saving: No need to consider fire separation distances, allowing for more flexible layout

 

Why Choose Our Dry-Type Transformer? 

Professional manufacturer among the earliest in China to obtain product type certification 

Scientific formulations and strict process control 

High-standard testing system ensures quality 

Professional team provides technical support

 

Product Keywords: 11KV 22KV 33KV 35KV Dry-Type Transformer, Epoxy Resin Cast Transformer, SC(B) Series Transformer, Low Loss Transformer, Explosion-Proof Transformer, IP23 Protection Transformer, Substation Equipment, Distribution Transformer Upgrade, Energy-Efficient Power Transformer

Applicable Industries: Power Systems, Construction Engineering, Municipal Engineering, Transportation, Medical Facilities, Commercial Real Estate, Industrial Plants