Our LV Low Voltage Switchgear is a type-tested low voltage power distribution assembly designed strictly according to IEC 61439 standards, widely supplied for Tanzania electrical infrastructure, power substations, mining sites, industrial plants, commercial buildings and compact prefabricated substations. This LV switchgear cabinet works for 400V three-phase 50Hz power system, matching the mainstream grid standard in Tanzania. It is used for receiving, distributing and protecting low-voltage electric power, with functions of overload, short-circuit and earth fault protection, motor control and power metering. Xinhong Electrical manufactures custom LV switchgear for Tanzania customers. We adopt galvanized steel enclosure, modular drawer or fixed compartment structure, support Form 2b / Form 3b / Form 4b internal separation. We can configure ACB, MCCB, contactors, relays, smart meters and monitoring modules as requested. With CE, ISO certification and tropical anti-corrosion treatment, our low voltage switchboard adapts to Tanzania’s high temperature and humid tropical environment, resisting dust and moisture to reduce onsite failure risk. We support full custom layout, busbar current grade, IP protection grade and local certification documents for Tanzania TBS inspection. Our factory has rich experience cooperating with EPC contractors, power developers and substation projects across Tanzania.
| Item | Parameter |
|---|---|
| Product Name | LV Low Voltage Switchgear / Low Voltage Switchboard |
| Rated Operational Voltage | AC 400V (380V / 415V optional) |
| Rated Frequency | 50Hz (Tanzania grid standard) |
| Rated Current of Main Bus | 630A ~ 6300A |
| Short-time Withstand Current | 25kA, 50kA, 80kA / 1s |
| Enclosure Material | Cold rolled galvanized steel, 304 stainless steel optional |
| Protection Degree | IP30 / IP40 / IP43 / IP54 |
| Internal Separation Form | Form 2b, Form 3b, Form 4b |
| Standard | IEC 61439-1, IEC 60947, CE, ISO9001 |
| Structure Type | Fixed type, Drawer type (MCC) |
| Busbar Material | Electrolytic copper (aluminum busbar optional) |
| Working Ambient | -5℃ ~ +55℃, tropical anti-moisture & anti-dust treatment |
A: Yes. Our LV low voltage switchgear is designed for AC 400V 50Hz system, which matches Tanzania power grid. We also provide documents complying with Tanzania local standard DTZS-IEC 61439 for project approval.
A: Fully custom available. We can arrange ACB, MCCB, metering, protection relay and communication modules as your single line diagram. We support brand selection of electrical components.
A: For indoor substation room: IP30~IP40. For semi-outdoor or high dust mining site: IP54 with tropical anti-corrosion coating.
A: Yes. We provide factory test report, CE certificate, ISO certificate, packing list, commercial invoice and certificate of origin to support Tanzania customs clearance and TBS inspection.
A: Perfect match. It is widely used as the low voltage side cabinet for 11kV / 33kV distribution transformers and prefabricated substations in Tanzania.